AW: Enabling New Function Clist

AW: Enabling New Function Clist

 

  

Hi James,

"E37 with reason code 04" means, that you are running out of space on all volumes:

E37
Explanation: The error occurred when an output operation was requested.
The data set was on a direct access or magnetic tape device. This system
completion code is accompanied by message IEC032I. Refer to the
explanation of message IEC032I for complete information about the task
that was ended and for an explanation of the return code (rc in the
message text) in register 15.

Application Programmer Response: Respond as indicated for message
IEC032I.

System Programmer Response: If the error recurs and the program is not in
error, look at the messages in the job log for more information. Search
problem reporting data bases for a fix for the problem. If no fix exists,
contact the IBM Support Center. Provide the JCL and the program listing
for the job.

..........

Return Code Explanation
04 A data set opened for output used all space available to or on
the current volume, and no more volumes were available. Change
the JCL to specify more volumes.

1. Not enough volumes were specified for the data set, through
the SER, volume count, or REF subparameter of the VOLUME
parameter of the DD statement. When all the volumes were
filled, the program attempted to write another record.

2. For a partitioned data set on a direct access volume or for
a VIO data set, all space was filled when the program
attempted to write another record. (A partitioned data set
or a VIO data set can reside on only one volume with a
maximum of 65535 tracks.)

3. For a partitioned data set on a direct access volume, 16
extents had been used when the program attempted to write
another record.

Hth
Simone Klein
Cologne, Germany

-----Ursprüngliche Nachricht-----
Von: JAMES PARK [mailto:db2udbdba-ezmlmshield-x35662476.[Email address protected]
Gesendet: Dienstag, 29. Januar 2008 20:03
An: LazyDBA Discussion
Betreff: Enabling New Function Clist

Dear listers,

z/OS V8.

While working with V8 Enabling New Function CLIST I got this error message. I don't know how A90109.compress.temp dataset gets created.

DSNT478I BEGINNING EDITED DATA SET OUTPUT
IEC032I E37-04,IFG0554P,A90109,IKJACCNT,OUTPUT1,6847,TSMS54,A90109.COMPRESS.TEM
P
IEA995I SYMPTOM DUMP OUTPUT
SYSTEM COMPLETION CODE=E37 REASON CODE=00000004
TIME=13.41.08 SEQ=06376 CPU=0000 ASID=00C8
PSW AT TIME OF ERROR 075C1000 80D5ECDE ILC 2 INTC 0D
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW 00D5ECD8 - 41003846 0A0DB20A 00509808
GR 0: 00D5EEE8 1: A4E37000
2: 000A81D0 3: 00D5E6A2
4: 0076A208 5: 00D74000
6: 0076A4AC 7: 0076A504
8: 0076A4CC 9: 0076B4F8
A: 00EB4EE8 B: 000A84D8
C: 0076B4F8 D: 00000080
E: 00D5EB04 F: 00000004
END OF SYMPTOM DUMP
IKJ79102I CALL ENDED DUE TO ERROR+
IKJ79102I SYSTEM ABEND CODE E37 REASON CODE 0004
COMPRESS FAILED FOR DATASET SYS1.DB2.V810.DB2V.NEW.SDSNSAMP
REASON: IEBCOPY UTILITY CANNOT COMPLETE SUCCESSFULLY
***


Thanks,

James Park
Database Specialist II
Annapolis Data Center
410-260-7489
[Email address protected]




------------------------------------------------------------------------------
This email and any file transmitted with it may be confidential and are intended solely for the use of the individual or entity to whom they are addressed. If you received this email in error, please notify the Comptroller's System Manager by forwarding this message to [Email address protected]
==============================================================================



---------------------------------------------------------------------
TO REPLY TO EVERBODY , PLEASE CLICK REPLY-ALL, NOT JUST REPLY
To post a dba job: http://jobs.lazydba.com
To Subscribe : http://www.LazyDBA.com
To unsubscribe: http://www.lazydba.com/unsubscribe.html


DB2 & UDB email list listserv db2-l LazyDBA home page